TICO Document #: SFN-20250828A
Description of Procedure: KUS DEF TANK Maintenance Instructions
Instructions:
Park vehicle on a flat surface, apply parking brake and chock wheels. Perform the lock-out tag-out procedure.
Functions of Urea Tank Assembly | ||
---|---|---|
NO. | DESCRIPTION | MAIN FUNCTION |
1 | Air Vent | Balancing air pressure inside and outside the tank to ensure no urea refilling failures, to ensure the work of the urea tank. |
2 | Sensor | Urea suction for supply to the system in a certain amount to keep it running in accordance with the indication of SCR system, continuous detection of urea solutions volume and temperature in the tank. |
3 | Tank cap | Sealing urea filling port |
4 | Magnetic filler port | Cooperate with filling gun to realize automatic filling and gun jumping |
5 | Filter | Filtering urea impurities |
6 | Tank body | Urea storage |
7 | Drain port | Clear up urea residuals inside the tank, avoid the impurities cumulated at the bottom of the tank, mainly used in tank cleaning process. |
Comments of DEF Refilling Operations | ||
---|---|---|
| ||
Maintenance frequency of Urea Tank Assembly | ||||
---|---|---|---|---|
NO. | Parts | Frequency | Maintenance Requirement | Effect |
1 | Tank body | Once a year or every 2000hrs | Clean the impurities and foreign objects in the tank |
|
2 | Filter of filler neck | Once a year or every 2000hrs | Disassemble and clean |
|
3 | Air vent | Half a year or 1000hrs |
| Tank is collapsed |
4 | Filter of sensor tube | N/A | If clogged, remove the filter and clean out foreign matter | Can not suck urea properly. |
5 | Filter of coolant tube | 1-First maintenance half a year or 1000hrs. 2-After that, every 3500hrs. | Remove foreign matter from the filter | Sensor heating and thawing function fail. |
Empty and clean the tank body | |||
---|---|---|---|
| |||
1) | 2) | 3) | 4) |
Remarks: Should keep tank without water after cleaning, otherwise it will affect the urea concentration. |
Disassemble and clean the filter of filler neck | ||
---|---|---|
| ||
1) | 2) | 3) |
4) | 5) | Remarks:
|
Disassemble and clean the air vent | ||
---|---|---|
| ||
1) | 2) | 3) |
Remarks:
|
Disassemble and clean the filter of coolant tube | |||
---|---|---|---|
| |||
1) | 2) | 3) | 4) |
Remarks:
|
Failure mode and service of Urea Tank Assembly | ||||
---|---|---|---|---|
NO. | Failure mode | Cause | Actions | Remarks |
1 | Difficult filling | Block at the filter of the filler neck | Clean the filter of filler neck | In dusty climates, increase the cleaning frequency appropriately |
2 | Air vent failure during filling | Block at the air vent | Replace the air vent Check the tube | In dusty climates, increase the cleaning frequency appropriately |
3 | Severe expand of the tank in cold weather | Excessive filling | After thawing, extract a portion of the solution | Follow the refilling principle, do not refill too much |
4 | Poor ventilation of coolant tube | Filter is clogged | Clean or replace the filter | Impurities in cooling water, increase the cleaning frequency appropriately |
5 | Sensor level remains constant | Float is stuck | Remove sensor, check the float, remove the impurities | Should fill standard urea, keep clean |