SFN-20250130 CID and VIM Update Required

Prev Next

TICO Document #: SFN-20250130 CID and VIM Update Required

Description of Procedure: All Pro-Spotters with Volvo Penta Powertrain are required for security and operating system updates

Units Affected: Volvo Penta Powertrain

Parts Required: TVC 49 Diagnostic Software, USB Link 3 or PCAN Cables

Planned Labor: 60 minutes


Inspection:

  • Turn vehicle on so that the CPAC display is running

  • Confirm that the CPAC display has good Internet and GPS signal

  • Confirm that your diagnostic tool is charged or A/C power during this operation

  • Enter general settings menu by dragging down twice on the screen and pressing the gear icon

  • Go to information center and confirm unit is 5.5 or newer (TVC0.2.29.19 on the display, 19+ is newer)

    • If older please contact your field service manager for additional information

  • If you don’t have TVC 49 please download from TICO Knowledge here <Link>

  • Book time in EDGE under operation code 8.153 - CPAC CID and VIM Update

!!!!!USE ScanDisk SDCZ50 Thumb Drives Only!!!!

Download these files before leaving the dealership and request access code from TICO (Connect Truck to Geotab step)

Required Files:

VIM 5.6 File

vim_0.0.17.1_P0004961R1U_TICO_Aftermarket
1.09 MB

CID Update 5.6 File

CIDUpdate56
5.15 MB

CIDSW File

CidSwPackage_169_INTERNAL_USE_ONLY.enc

Commissiong the CID: (Frame Numbers 13724 and 13723)

  1. From the Update Settings Menu press device commissioning


  2. Enter the code (JNHK2B) in the field - Make sure you have internet connection with the CID


  3. Press enter, the device will now be commissioned


  4. Request a new update file to lucas.rochard@cpacsystems.se


  5. Follow the Updating the CID steps


Updating the CID:

  1. Download the CIDUpdate56.zip and CIDSW.enc files from TICO Knowledge


  2. Load the zip file on a USB Drive


  3. Insert the USB drive into the back of the Display


  4. Enter the general setting menu by dragging down twice on the screen and pressing the gear icon (Item 5)


  5. Go to software update


  6. Then press USB update


  7. Press verify


  8. Press proceed with updates


  9. The CID will restart and update the platform (~5 minutes)


  10. Start the display after the platform, still with the USB inserted in the CID


  11. A pop-up with USB update should show up


  12. Verify


  13. Proceed with updates

Updating the VIM:

  1. Download the VIM Package File


  2. Connect to a truck


  3. Start the TVCFlash while truck is on


  4. Drop the package file in the “Flash” tab, and program


Connect Truck to Geotab:

  1. Start the CPAC Display


  2. Enter the retarder setting by pressing the gear on the display (Item 5)


  3. Press on the bottom left of the window


  4. Press prod and enter the invite code provided (use Daily Codes Link or email your Field Service Manager or Uptime Center)


  5. The CID will restart