.png?sv=2022-11-02&spr=https&st=2025-12-19T15%3A24%3A04Z&se=2025-12-19T15%3A35%3A04Z&sr=c&sp=r&sig=FgDvVzVZ4R7DIN2ikderuPIcIogIpmVcwvY0WDdbYZs%3D)
TICO Document #: SFN-20231015B (formerly TES-234)
Complication: The mid-mounted magnet can move excessively due to road contact, possibly damaging the CNG pressure relief device (PRD) vent line.
Description of Procedure: Install a guard to shield the PRD vent line from the magnet’s excessive movement
Units Affected: CNG-powered vehicles with a mid-mounted magnet
Parts Required: KIT, CNG PRD VENT GUARD 970038
Planned Labor: 15 minutes
Instructions:
Park the vehicle on a flat surface, apply a parking brake, and chock wheels. If your company utilizes a “Lock Out, Tag Out” policy, you should employ it during this procedure.

Locate the PRD vent line. It is a ½” stainless steel tube located behind the rearward fuel tank mounting bracket. If the vent line has been damaged, then it must be replaced. See Figure #2.
Note: The PRD vent line is not a fuel line and does not contain any natural gas during normal operation. It is a safety device that allows the fuel tank to release excess pressure. Thus, a damaged vent line must be replaced.

To install the vent line guard, remove the (2) 3/8”-16 bolts that mount the pass-thru plate to the fuel tank bracket. See Figure #3.
Discard the bolts, but retain the washers for later use.

Using the (2) 3/8”-16 bolts provided in the kit and the retained washers, install the guard (P/N 123155) onto the backside of the fuel tank bracket. See Figure #4.

Remove the “Lock Out, Tag Out” plaque.
Return the vehicle to service.