SFN-20230719-A Work Light Field Update

Prev Next

TICO Document: SFN-20230719A

Complication: Potential issue with shorting of harness, 3-minute timer due to the current wiring is 14awg and requires that it be protected by a maximum fuse size of 25A

Units Affected: Units with Assembly 722795

Description of Procedure: Installation of inline fuse on harness 621330

Parts Required: 970120

Planned Labor: 2 Hours


Instructions:

  1. Install 5/16 ring terminal P/N 910459 on one end of inline fuse P/N 910680 on the other and heat shrink over wire and terminal end


  1. Remove BATT PWR from rear terminal of RTMR


  1. Cut off Power ring terminal on P/N 621330


  1. Splice together “Batt PWR” red wire with inline fuse using splice kit PN 910716


  1. Install on terminal of RTMR


  1. Install 20A ATM fuse PN 91025


Overview of repair


Machine Index Affected:

751229

751269

751329

751332

751365

751368

751371

751372

751392

751471

751472

751548

751549

751554

751556

751636

751637

751641

751642

751671

751737

751744

751756

751784

751853

751855

751856

751857

751858

751921

751922

751923

751927

751936

751937

751938

751960

751965

751966

751967

751968

751969

751970

751978

752039

752040

752041

752055

752056

752183